OPERATION
?
N O T E
After the heating operation is stopped, the fan mode may be operated
for approximately 2 minutes.
7.2 OPERATION MODE (COOLING,
HEATING, DRY, AUTOMATIC COOLING/
HEATING AND FAN OPERATION)
Function
Cooling operation (COOL): to decrease the room
temperature.
Heating operation (HEAT): to increase the room
temperature.
Dry operation (DRY): to decrease the humidity in the room.
Automatic cooling/heating operation (AUTO): to cooling and
heating automatic changeover.
Fan operation (FAN): to circulate the air in the room.
?
N O T E
The recommendable set temperature is as follows:
Cooling operation: 27 to 29ºC
Heating operation: 18 to 20ºC
Dry operation: 23 to 25ºC
7.3 SETTING METHOD
?
N O T E
The "
" lamp (yellow) is turned ON with the beep sound for
receipt confirmation.
The beep sound may not be heard by surrounding noise.
To adjust the air flow angle, refer to the installation and operation
manual of indoor unit.
Temperature setting
Point the transmitter towards the receiver kit and press "TEMP."
switch to set the temperature.
By pressing "
", the temperature is increased by 1ºC (or
0.5ºC*).
By pressing "
", the temperature is decreased by 1ºC (or
0.5ºC*).
The set temperature is set to 28ºC in the
cooling operation
* Configuration selecting temperature setpoint by 0.5ºC depends
on Indoor unit type. If not available, make it by 1ºC.
?
N O T E
The temperature is not displayed during the stoppage. In the case
that the temperature is set during the stoppage, the temperature
indication is turned ON temporally. It is automatically turned OFF
after setting.
The temperature can be set for each operation mode.
The setting temperature is available from 17ºC to 30ºC by the
wireless remote control switch. However, for indoor unit which
setting temperature range is 19 ~ 30ºC, the temperature settings of
17ºC and 18ºC are not available.
Fan speed
Point the transmitter towards the receiver kit and press "FAN"
4
PMML0414A rev.5 - 06/2019 - P5416676
switch to set the fan speed.
The fan speed is set to "High" in the
cooling operation.
By repeatedly pressing the switch, the setting will change
sequentially through Auto, Low, Med, High and High2.
?
N O T E
The fan speed is not displayed during the stoppage. In the case that
the fan speed is set during the stoppage, the fan speed indication is
turned ON temporally. It is automatically turned OFF after setting.
The fan speed can be set for each operation mode. However, the
fan speed will be fixed at "LOW" in dry operation.
Air flow direction
1 Point the transmitter towards the receiver kit and press
"LOUVER" switch to set the louver angle.
The louver angle is set to 1 step
at "High" in the cooling operation.
2 By pressing "LOUVER" switch, the louver angle will be
changed as follows.
: Auto swing operation will be started. At this time, the
louver will swing repeatedly on LCD.
?
N O T E
The louver angle is not displayed during the stoppage.
The louver setting are only available from 1 step through 5 step and
auto swing at the cooling and dry operation modes.
The louver angle may be changed automatically during the heating
operation. (Refer to the installation and operation manual of indoor
unit about detail.)
The louver may NOT stop immediately right after the switch is
pressed.
To adjust the louver angle, refer to the installation and operation
manual of indoor unit.
Auto
Low
Med
High
High 2