Type C (separate ø 80 flues)
KEY
1
90° MF polypropylene curve (6 pcs.) code 8077450
2 a Polypropylene extension L. 1000 (6 pcs.) code 8077351
2 b Polypropylene extension L. 500 (6 pcs.) code. 8077350
3
Hinged tile code 8091300
4
Roof terminal kit L. 1381 code 8091204
4 a Coaxial roof exit terminal code 8091205
5
Polypropylene extension L. 250 with socket code 6296513
6
45° MF polypropylene curve (6 pcs.) code 8077451
7
Exhaust terminal code 8089501
8
Internal-external ring nut kit code 8091500
9
Air inlet terminal (supplied with unit)
10
Inlet/exhaust fitting code 8091401
11
Rubber gasket ø 80 (supplied as standard)
12
Condensation recovery L. 135 code 8092800
13
Coaxial exhaust ø 80/125 L. 885 code 8091210
G
M
TABLE OF LOAD LOSSES OF ACCESSORIES
R
STAFFA TELAIO
CALDAIA
90° MF polypropylene curve
45° MF polypropylene curve
Polypropylene extension L. 1000
Polypropylene extension L. 500
Coaxial roof exit terminal + Fitting (pos. 10)
Roof exit terminal L. 1381
Exhaust terminal
Air inlet terminal
Polypropylene extension L. 250 with socket
Coaxial exhaust L. 885 + Fitting (pos. 10)
Condensation recovery L. 135
WARNING:
- Installations with roof exit terminal (4a) and coaxial exhaust (13) require the use of a condensation reco-
very (12) that has to be connected to the water drain siphon (waste water).
- The installation of the roof exit terminal (4a) requires the removal of the two ø 60 and ø 100 reducers.
- Before installing accessories, lubricate the internal part of gaskets with silicon-based products. Avoid
using oils and greases.
Load loss
(mm H
O)
2
Pmin
Inlet
Exhaust
2,3
3,5
Pmax
1,7
2,3
1,4
1,4
0,7
0,7
-
16,0
-
5,0
-
4,0
1,8
-
-
0,3
-
17,0
5,8
-
Type C (separate ø 80 flues and
coaxial exhaust terminal)
WARNING !
When load loss of the individual accessories con-
nected exceeds i 4 mm H
O, to assure correct opera-
2
tion of the appliance, do as follows:
- set the installer parameter PAR 9 as indicated in
TABLE 2 (see point 3.3 to access the installer para-
meters).
TABLE 2
Load loss
(mm H
O)
2
0 - 4
4 - 8
8 - 12
12 - 16
16 - 20
20 - 24
24 - 28
28 - 32
32 - 36
36 - 40
40 - 42
- proceed with calibrating CO
minimum capacity as specified in point 4.2.2.
PAR 9
(long chimneys)
0
1
2
3
4
5
6
7
8
9
10
at the maximum and
2
Fig. 7
67