10
11
D
9
8
Codice/Code 8113350
Modello/Model MURELLE HE 110 R ErP
Matricola/Serial n. 9999999999
PAR 1 = 68 (G20) / 70 (G31)
PAR 2 = 5
4.5
MAINTENANCE (fig. 20)
To guarantee functioning and efficiency of
the appliance, in respect of the legal pro-
visions in force, it must be regularly che-
cked; the frequency of the checks depends
on the type of appliance and the installation
and usage conditions.
In any case, it should be inspected at least
once a year by a qualified technician.
During maintenance operations, it is
important to verify that the drip-plate
with drain trap contains water (this check
2
C
1
1
ATTENTION
Before removing or refitting
the front panel of the boiler,
open the small upper pla-
stic door.
is particularly important if the generator
has not been used for extended periods
of time).
If necessary, the drip plate can be filled
using the tap provided (fig. 20).
5
4.5.1
Chimney sweep function (fig. 21)
To check boiler combustion, press the
3
installer's key
for a few seconds. The
chimney sweep function will switch on and
1
will continue for 15 minutes.
From that moment, the boiler will start
2
7
6
D
5
4
3
ES
PT
ENG
B
A
Fig. 19
Fig. 20
79