Error code
Problem
The display board cannot
E0
receive the signal from the
filter board.
The display board cannot
EA
receive a signal from the
power board.
Failure of the temperature
F3
sensor of the ceramic plate -
short circuit.
Failure of the temperature
F4
sensor of the ceramic plate -
open circuit.
Failure of the temperature
F5
sensor of the ceramic plate -
invalid.
Failure of the temperature
F9
sensor of the IGBT - short
circuit.
Failure of the temperature
FA
sensor of the IGBT - open
circuit.
Solution
No automatic recovery
Check the connection between
the display board and the filter
board. Replace the filter board
if necessary.
Check the connection between
the display board and the
power board. Replace the
power board if necessary.
Check the connection or
replace the temperature
sensor of the ceramic plate. If
this does not correct the error,
replace the power board.
Replace the power board if
necessary.