5-9.Ref lected Temperature
• Using the offset factor, the reflection is calculated out due to the low emissivity and the accuracy of the
temperature measurement with infrared instruments is improved.
• In most cases, the reflected temperature is identical to the ambient air temperature.
• Only when objects with strong emissions with much higher temperature are in the proximity of the object
being measured should be determined and used.
• The reflected temperature has only little effect on objects with high emissivity.
• The reflected temperature can be set individually.
• Follow these steps to get the right value for the reflected temperature.
1. Set the emissivity to 1.0.
2. Adjust the optical lens to near focus.
3. Looking in the opposite direction away from the object, take a measurement and freeze the image.
4. Determine the average value of the image and use that value for your input of reflected temperature.
5-10.Thermal Imager Reporter Software
• Thermal Imager Reporter software is supplied with the Thermal Imager.
• This Software is intended for Thermal Imager and contains feature to analyze images, organize data and
information, and make professional reports.
• Thermal Iimager Reporter software allows audio annotations and commentary to be reviewed on a PC.
10
Operating Instruction for Thermal Imager / English
6.Menus
The menus, together with buttons, are access for image, measurement, Emiss, Palette, temperature
measurement range, take photo and video, review, and settings.
6-1.Main Menu
• Press "Menu/OK" Button or touch the screen, the main menu will be poped up.
• Main Menu is the main interface of the Thermal Imager's menus.
• It contains five items such as Measure parameters, Measure tools, Image mode, Palette, system Settings.
Alarm: Set alarm temperature
Paramters: Parameters set for the calculation temperature.
Measure Tools: Set for the calculation and display of radiometric temperature measurement data
related to the thermal images.
Image Mode: Set image source for the display on the Thermal Imager's LCD. It contains five items
such as infrared image, visual image and fusion.
Palette: Set the type of color bar.
Settings: Set for the user preferences such as language, unit of temperature measurement, date,
time;restore factory setting and display product information.
6-2.Image Mode
1. ln main menu, press "Image Mode" icon button, highlight "Image Mode".
2. Press "Up" button, popup Image submenu which contains five image modes.
3. Press "Left" or "Right" button, or touch the image mode icons, highlight the Image mode which you
want to choose.
4. The image mode will change after you choose it.