FriwaMaster
1.2
Valve logics
2
Installation
2.1 Mounting
screw
front cover
fastening
fastening
The FriwaMaster controls the electromagnetic valves by
means of relays. When the relay is energised, the valve is
opened.
push-push locking mechanism
push to open
push to close
The unit must only be located in dry interior locations. It
is not suitable for installation in hazardous locations and
should not be placed close to any electromagnetic fields. The
controller must additionally be supplied from a double-pole
switch with contact gap of at least 3 mm. Please pay attenti-
on to separate routing of sensor cables and mains cables.
1. Open the front cover by pushing it. Unscrew the cross-
display
2. Mark the upper fastening point on the wall and drill and
push buttons
3. Hang the housing from the upper fastening point and
fuse T4A
4. Hang the housing from the upper fastening point and
5. Carry out connection in accordance with the terminal
6. Insert cover and attach with the cross-head screw. Close
144 mm
WARNING!
Always disconnect the controller
from power supply before open-
ing the housing!
head screw from the cover and remove it along with the
front cover from the housing.
fasten the enclosed wall plug and screw leaving the head
protruding.
mark the lower fastening point through the hole in the
terminal box (centres 135 mm). Drill and insert the lower
wall plug.
attach with the lower screw.
allocation.
the front cover properly.
19
|