FriwaMaster
3.
Operation
3.1 Buttons for adjustment
control lamp
(-) backwards
2
SET / OK
(selection / adjustment mode)
3.2 Control lamp
3.3 User code
22
|
forwards (+)
1
3
The controller is operated via the 3 push buttons below the
display. The forward-button (1) is used for scrolling forward
through the menu or to increase the adjustment values.The
backward-button (2) is similarly used for scrolling backwards
and reducing values.
Button 3 is used for adjusting the individual parameters.
Press the button in order to access the sub-menu or the
SET mode. Button 3 is also used for confirmation.
By selecting the menu line „back" and pressing the SET/OK
button, the display returns to the main menu. If no button
is pressed within 60 seconds, the display changes back to
the main menu.
Note: The choice of adjustment values and options depends
on different functions and the user code. Some only appear
in the display if they are available for the adjusted system
parameters.
The controller is equipped with a red-/green control lamp.
The following control and system status are signalled as
shown:
•
green:
normal operation / initialisation
•
green flashing:
manual mode
•
red flashing:
malfunction of the system
User
Code 119
Adjustment values can be accessed.
Customer
Code 000
Measured values and balance values are
accessible. Adjustment values can be altered
partly.
For safety reasons, the user code should ge-
nerally be set to "000" before the controller
is handed to the customer!
Note:
After the menu point "user code" has been choosen,
enter the user code!