FriwaMaster
5
2.2.3 Relay outputs
load terminals
neutral conductor-common terminal block
protective conductor-common terminal block
2.2.4 Data transfer / bus
RESOL VBus®
connection terminals
2.2.5 Mains supply
5
The controller is equipped with 5 relays in total to which
loads, such as pumps, valves and auxiliary relays can be
connected:
• Relays R1 to R4 are electromechanical relays:
R1 ... R4 = normally open R1 to R4
N
= neutral conductor N (common terminal block)
PE
= protective conductor PE (common terminal
block)
• Relay R5 is a potential-free relay with changeover
contact:
R5-M
= center contact
R5-A
= normally open
N
R5-R
= normally closed
N
= neutral conductor N (common terminal block)
PE
= protective conductor PE (common terminal
block)
PE
R1
R2
5
module 1 module 2 module 3 module 4
The controller is equipped with the RESOL VBus
transfer. The connection is carried out at the two terminals
marked "VBus
" (either polarity).
®
The power supply to the controller must be carried out via
an external power switch (last step!) and the supply voltage
must be 220 ... 240 V~ (50 ... 60 Hz). Flexible cables must
be attached to the housing with the enclosed strain relief
and the corresponding screws or be run into the controller
housing in a cable conduit.
fuse
mains terminals
neutral conductor N (common terminal block)
protective conductor PE (common terminal block)
R3
R4
R5
error relay
/ return
connec tion
for data
®
21
|