Ensure sufficient ventilation at the working place.
Remove the refrigerant. If the recovery is not required by
national regulations, drain the refrigerant to the outside.
Take care that the drained refrigerant will not cause any
danger. In doubt, one person should guard the outlet.
Take special care that drained refrigerant will not float
back into the building.
Evacuate the refrigerant circuit.
Purge the refrigerant circuit with nitrogen for 5 min.
Evacuate again.
Cut out the compressor and drain the oil.
Transportation, marking and storage for units that em-
ploy flammable refrigerants
Transport of equipment containing flammable refriger-
ants
Attention is drawn to the fact that additional transportation
regulations may exist with respect to equipment containing
flammable gas. The maximum number of pieces of equip-
ment or the configuration of the equipment, permitted to be
transported together will be determined by the applicable
transport regulations.
Marking of equipment using signs
Signs for similar appliances used in a work area generally
are addressed by local regulations and give the minimum
requirements for the provision of safety and/or health signs
for a work location.
All required signs are to be maintained and employers
should ensure that employees receive suitable and suffi-
cient instruction and training on the meaning of appropri-
ate safety signs and the actions that need to be taken in
connection with these signs.
The effectiveness of signs should not be diminished by too
GB
125