Nailer Actuation
Nosepiece must be in full
contact with the work sur-
face . Gap between the nosepiece and the work
surface may result in deflection of the fastener
and property damage or personal injury .
Never wedge the nosepiece
between two or more sur-
faces . Gap between the nosepiece and multiple
work surfaces may allow deflection of the fas-
tener and property damage or personal injury .
Never hold back the nose-
piece
Holding the nosepiece back can result in unex-
pected actuation and may cause property dam-
age or serious injury .
Never position your face or
body over the nailer top cap
during operation . Sudden recoil can result in
impact to the body and injury .
This nailer operates only in a fully sequential
mode, steps 5–7 must be repeated sequentially
for intended operation of the nailer .
(Fig . 19, 20)
Assemble the needed Nosepiece and Magazine
as described in the "Removing and Installing the
Magazine and Nosepiece" section .
1 . Insert the Battery Pack .
2 . Press and hold the ON/OFF Button to acti-
vate the nailer .
3 . Press the Trigger Lock 3 to unlock the Trigger
2 (Fig . 19) .
4 . Firmly grip of the nailer's handle and hold
the nailer perpendicular (90º angle) to the
work surface (Fig . 20), and use your free
hand to hold the top cap for added stability .
5 . Press the Nosepiece 8, 15
the work surface . If the Nosepiece is not
fully pressed into the nailer, the nailer will
not fire .
6 . Press the Trigger 2
er into the worksurface . The trigger has
to be pressed within 2 seconds after the
Nosepiece is fully pressed . If the trigger is
pressed later, the nailer will revert to a SAFE
mode and the actuation sequence will have
to be repeated .
22
1605A001CD GNB18V-12 202301.indd 22
page heading
Operation
during
operation .
fully against
A
to drive the fasten-
B
Fig. 19
2
3
A
8
Fig. 20
B
5