Descargar Imprimir esta página

Bosch GNB18V-12 Instrucciones De Funcionamiento Y Seguridad página 25

Publicidad

Idiomas disponibles

Idiomas disponibles

Status
Status
Light Color
GREEN
NORMAL
Jam condition
RED
detected
Motor and Electronics
YELLOW
Overheat protection
Nailer Low Tempera-
DARK BLUE
ture Protection
Motor Blocked -
Motor cannot return
ORANGE
driver blade to
correct position
Motor Overcurrent
LIGHT BLUE
Protection
Electronics Fault -
WHITE
Nailer in SAFE mode
Service
MAGENTA
Recommended
1605A001CD GNB18V-12 202301.indd 25
Troubleshooting
Condition
Nailer is energized
and operating
conditions are normal
1) Follow the "Jam clearing" sequence to remove the
obstruction in the Nosepiece or Magazine.
The driver blade
cannot return to
2) In the RESET mode, if other abnormal conditions
correct position
are encountered, the status indicator will display the
appropriate status light color.
Motor or electronics
Allow the nailer to cool. When the motor and
temperature is above
electronics cool sufficiently, the nailer will self reset
50°F (122°C).
and resume normal operation.
Place nailer in warm space. When the motor and
Nailer temperature is
electronics warm sufficiently, the nailer will self reset
lower than 23°F (-5°C).
and resume normal operation.
1) Follow the "Jam clearing" sequence to remove the
Drive mechanism
obstruction in the Nosepiece or Magazine.
is obstructed,
2) In the RESET mode, if other abnormal conditions are
preventing normal
encountered, the status indicator will display the ap-
reset operation.
propriate status light color.
1) If nailer is being fired for extended periods without
sufficient cooling, allow the nailer to cool.
2) Examine nailer for obstruction or excessive
Motor is drawing
contamination.
excessive current
- Nailer will stop
3) Error will clear if battery is removed or nailer is
operation.
turned OFF.
4) If error persists, nailer needs to be returned for
repair at a Bosch service center.
Electronics fault
This condition is Non-resettable and non-repairable by
detected preventing
user. Nailer needs to be returned for repair at a Bosch
operation.
service center.
Service-indicator
illuminates MAGENTA
Return to Bosch service center for service.
for 3 seconds, then
shows normal green.
User Action
Nailer is ready for use
25
1/9/23 2:07 PM

Publicidad

loading