Removing thermocouple B201 / B211
a
The electrical compartment is open.
a
The pan cover has been removed.
1. Open the nut of the thermocouple with a spanner (size 19 mm).
2. Pull the thermocouple with the seal out of the hole.
3. Unplug the thermocouple from the I/O board.
4. Disconnect the thermocouple cable from the harness or leave it disconnec-
ted in the unit.
>>
The thermocouple has been removed.
Installing the thermocouple
a
The thermocouple is ready for use.
1. Connect the cable to the I/O board.
2. Pull the cable through the pan axis.
3. Screw the nut of the thermocouple onto the thread on the front of the pan.
>>
The thermocouple is installed.
Closing the control panel
1. Proceed in reverse order to the step Opening the control panel .
Mounting the pan cover
1. Proceed in reverse order to the step Removing the pan cover.
Allocation is only necessary if several thermocouples have been exchanged.
Performing the allocation
a
The unit is connected to the mains.
a
The unit is switched on.
MI_2062_Removal_and_Installation_Thermocouple_B201_B211_S