WIRELESS 7-IN-1 SENSOR MAINTENANCE
REPLACE THE WIND VANE
Unscrew and remove the wind
vane for replacement
REPLACE THE WIND CUP
1. Unscrew and remove the
top cap
2. Remove the wind cup for
replacement
CLEANING HYGRO-THERMO
SENSOR
1. Remove the 2 screws at the
bottom of the radiation shield.
2. Gently pull out the shield.
3. Carefully remove any dirt or
insects on the sensor and
ventilation fan (do not let the
sensors inside get wet).
4. Clean the shield with water to
remove any dirt or insects.
5. Install all the parts back when
they are clean and fully dried.
TROUBLESHOOT
Problems
7-in-1 wireless sensor
is intermittent or no
connection
Indoor wireless sensor
is intermittent or no
connection
No WiFi connection
Data not reporting to
Wunderground.com or
weathercloud.net
Wunderground Precip.
Accum. Total graph offset
1 hour reset time, during
summer daylight saving
time
Solution
1. Make sure the sensor is within the transmission range
2. If it still not work, reset the sensor and resynchronize with
console.
1. Make sure the sensor is within the transmission range
2. Make sure the channel displayed match to the channel
selection on sensor
3. If it still not work, reset the sensor and resynchronize with
console.
1. Check for WiFi symbol on the display, it should be alway
on.
2. Make sure you connect to 2.4G band but not 5G band of
your WiFi router.
1. Ensure your Station ID and Station Key are correct.
2. Ensure the date and time is correct on the tablet . If
incorrect, you may be reporting old data, not real time data.
3. Ensure your time zone is set properly. If incorrect, you may
be reporting old data, not real time data.
1. Ensure the time zone of the device on Wunderground set
correctly
2. Ensure the time zone and DST on your console are correct.
3. If you located your station out of US time zone region in
Wunderground, the DST will be invalid. To solve this issue,
please turn off the DST function in console.
28
CLEANING THE RAIN
COLLECTOR
1. Rotate the rain collector by turning
it 30°anti-clockwise.
2. Gently remove the rain collector.
3. Clean and remove any debris or
insects.
4. Install the collector when it is clean
and fully dried.
CLEANING THE UV SENSOR
AND CALIBRATION
• For precision UV measurement,
gentle clean the UV sensor cover
lens with damp micro-fiber cloth.
• Over time, the UV sensor will
naturally degrade. The UV sensor
can be calibrated with a utility
grade UV meter, please refer to
Calibration section in previous
page for about the UV sensor
cablibration.