Descargar Imprimir esta página

Westinghouse WGen12000DFc Manual Del Usuario página 19

Publicidad

Idiomas disponibles

Idiomas disponibles

PAIRING THE REMOTE START
If the remote start key fob is replaced or needs re-paired to
the generator, follow this procedure.
Turn the generator battery switch to the ON position.
The power indicator light will illuminate.
Push and hold the red Pairing button on the back of the
control panel until the START/STOP button illuminates.
Push and hold the STOP button on the key fob until the
START/STOP button illumination turns OFF. Release
the button. The START/STOP button will illuminate after
the button is released.
START
STOP
Push and hold the START button on the key fob until the
START/STOP button illumination turns OFF. Release
the button. The START/STOP button will illuminate after
the button is released.
Push the Pairing button on the side of the control panel
until the START/STOP button illumination turns OFF.
Release the button.
Turn the generator battery switch to the OFF position.
The remote is now paired.
Key Fob
Activation Light
START Button
STOP Button
OPERATION
FUEL SELECTOR SWITCH
Position the fuel selector switch on the front control panel
to the desired fuel choice.
Push the fuel selector switch fully upward for gasoline
operation.
Push the fuel selector switch fully downward for propane
operation.
operation.
Vary the load occasionally to allow stator windings to heat
and cool and help seat the piston rings.
LOW IDLE
NOTICE
Always start the generator with Low Idle OFF. Allow the
engine speed to stabilize before switching Low Idle ON.
NOTICE
Frequency output of the generator is dependent on
engine speed. DO NOT use Low Idle when powering
sensitive electronics or large surge loads, such as an
air conditioner, electric pump, refrigerator, or when
connected to a home transfer switch.
Low Idle minimizes fuel consumption, noise, and engine
wear by lowering the engine RPM to idle (2400 RPM) when
electrical loads have been turned off and automatically
returns to rated speed when loads are turned back on.
Turn Low Idle ON when powering intermittent, non-
electronic loads, such as power tools at a construction site.
BEFORE STARTING THE GENERATOR
Verify that:
• The generator is placed in an safe, appropriate location.
• All loads are disconnected.
Westinghouse Outdoor Power Equipment | 19

Publicidad

loading