28/36
Troubleshooting
Display
Reason
F18
Hardware error
F19
Gap lifting module
connections e.g. 1 + 3;
module defective/not
detected
F20
Pressure wave sensor
is not detected
(missing, damaged)
F21
Control stops after
collision detection and
moves 25 mm back.
F22
Error at the position
measuring system
(Hall sensor)
F23 - F24 – only in connection with the "basic distribution", for details see the distribution's
operating manual.
F23
Not all control units
connected to the
distribution are of the
same type.
F24
a) New distribution was
not set to the correct
number of control units.
F32
Control units connected
to the distribution
have different
Firmware versions.
12.1 Display of the error-causing control unit [from FD 2020-08]
Control unit without distribution
Button / display
or
P11
P15 from FD 2021-09
Bosch Rexroth AG, MPS: Steuergerät, 3 842 564 712/2022-06
The solution
Push a button to reset the error.
If the error continues to exist, separate the control unit
from the mains for 20 seconds. Otherwise, contact the
service.
Check whether all lifting modules have been correctly
connected to the control unit. Push a button to reset
the error.
Remedy error. Further movement after push of a
button.
Remove collision. Further movement after push of
a button.
Check the connection line of the lifting module
and plug-in contact. Check / observe the height
difference. A lifting module may not move any more or
asynchronous ==> decommission and/or remove the
table top or assembly. Otherwise, contact the service.
Make sure that all connected control units are of the
same type.
a) See operating manual "Distributor basic, 2x4
Control"
See chap. 1.2
"Required and supplementary documentation".
This means that operation is not possible.
Contact the service.
Instruction / explanation
Call menu
Push to select a menu item