Trimmer unit no.: 54192:
Power supply .............................................................
Rated power input/output (W) ................................ 3700/ 3000
Rotary speed (min
Idle running speed (min
Protection / Protection class.......................................
Noise pressure level dB(A) L
Sound power level dB(A) L
Weight (kg) ................................................................
Heating plate no.: 54193:
Power supply .............................................................
Heating plate - diameter (mm) ................................ 850
Protection / Protection class.......................................
Weight (kg) ................................................................
Carrying frame no.: 54194:
Weight (kg) ................................................................
Hydraulic unit no.: 54177:
Power supply .............................................................
Rated power input/output (W) ................................ 1800/ 1500
Pump capacity (l/min) ................................................
Oil tank capacity (l) ....................................................
Pressure max. (bar) ...................................................
Hydraulic - Oil ............................................................
Dimensions (LxWxH, mm) .........................................
Protection / Protection class.......................................
Noise pressure level dB(A) L
Sound power level dB(A) L
Weight (kg) ................................................................
Control box modul no.: 54195:
Power supply .............................................................
Dimensions (LxWxH, mm) .........................................
Weight (kg) ................................................................
Overall length no.. 54190:
Total connected load (kW) .........................................
Transport case dimensions:
Basic unit (L x W x H, mm) ........................................
carrying frame + trimmer unit + heating element ........
(L x W x H, mm)
The noise level during operation can exceed 85 dB (A). Wear hearing protection!
Measured values determined in accordance with EN 61029-1!
3
Function of the Unit
3.1
Description
ROWELD P800B Professional is a compact, portable heating plate butt fusion welding machine
that were specially designed for use at the construction sites and in particular in pipe trenches.
Of course, the tools are very well suited for use in the workshop.
Welding of pipe-pipe connections, T-joints, pipe bends and welding neck can be made.
16
-1
) ..................................................
-1
) (milling disc) ......................
¦ K
..........................
pA
pA
¦ K
...........................
WA
WA
¦ K
..........................
pA
pA
¦ K
...........................
WA
WA
400 V, 50/60 Hz, 6,4 A
1400/ 70
23
I/ IP20
73 ¦ 3
84 ¦ 3
178,0
400 V, 50/60 Hz, 12000 W
I/ IP20
52
160
400 V, 50/60 Hz
10,3
4,75
0 - 138
HLP – 46 (no.: 53649)
750 x 360 x 380
I/ IP54
83 ¦ 3
94 ¦ 3
41
400 V, 3~ N, 50/60 Hz, 32 A
400 x 210 x 500
18
17
1500 x 2250 x 1850
850 x 1300 x 1920
ENGLISH