Transport and set the hydraulic unit only in a horizontal position. If it is set at an
angle, oil escapes from the vented plugs with the dipstick!
 Connect the hydraulic unit to the basic unit with both hydraulic hoses.
Protect the quick couplings from contamination. Replace leaky couplings immediately!
 Connect the mains plugs of control box modul to the power outlet/supply specified on the
type plates
 Connect the trimmer unit, hydraulic unit and heating plate mains plugs to the control box
modul.
 Switch on the main switch of control box modul.
 Set required temperature (cf. temperature controller).
The rise in temperature is indicated by a red signal lamp on the temperature controller.
The display generally indicates the actual temperature value. In accordance with national ordi-
nances and guidelines, e. g. DVS, the heating plate is ready after maintaining the setpoint tem-
perature for at least 10 minutes.
 Check the temperature with a temperature measurement device.
Risk of serious injury! The heating plate can reach temperatures of over 300°C /
572°F! We highly recommend storing the heating plate in the designated carrying
frame immediately after use!
The welding machine is equipped with a Type 400 digital temperature controller.
The digital temperature controller has been ideally configured and set before leaving our factory.
To set temperature simply press the Fkey until "_SP" is indicated in the display. The opera-
tor can now adjust the setpoint temperature between 0-300°C / 32-572°F with the arrow keys.
If no keys are pressed, the display indicates the actual temperature, the controller automatically
sets the new temperature parameter. As long as the actual temperature is lower than the set-
point temperature, the red arrow flashes (low). If the actual value is larger than the setpoint val-
ue, the red arrow flashes (high). If the actual temperature corresponds with the setpoint temper-
ature, the green bar illuminates. Should the actual surface temperature of the heating plate not
correspond with the actual temperature indicated, it is possible to enter an "offset". To define the
offset, press and hold the F key until "InP" appears in the display (approx. 7 sec.); release
F key, then press the F key as many times as required until "oFS" appears. Correct this
value as required. To save the new settings, press and hold F key until the actual value re-
appears in the display.
Warning! Do not change any other heating plate parameters!
Factory settings:
Menü „CFG"
„S.tu"
0
„h.Pb"
1.0
„h.lt"
0.68
„h.dt"
0.17
„h.P.H"
100
„rst"
0
„P.rE"
0
„SoF"
0
„Lb.t"
0
„Lb.P"
25
„FA.P"
0
18
Menü „InP"
„Ctr"
8
„tYP"
16
„FLt"
0.1
„FLd"
0.5
„dP.S."
0
„Lo.S"
0
„HI.S"
300
„oFS"
xx
„HI.A"
0
„Lo.L"
0
„HI.L"
280
ENGLISH
Menü „Out"
„AL.n"
0
„r.o.1"
0
„r.o.2"
0
„Ct.1"
20
„Ct.2"
20
„rEL."
0
Menü „PAS"
„Prot"
32