Descargar Imprimir esta página

HEIDELBERG Wallbox connect Serie Manual De Servicio página 31

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 93
1
N
L1
L2
L3 PE
Fig. 6
max. 2 Nm
Fig. 7
2
3
1
N
L1
L2
Cabling
4
5
2
S3
SW
EN
L3 PE
SW
When cabling the charging system, follow all instruc-
tions in chapter 1 and proceed as follows:
Appropriately prepare the mains connecting cable
(Ø 10 - 20 mm // max. 5*6 mm²) and connect it as
shown in Fig. 6 - no. 1. The illustration shows the
mains connection via three phases. Use N, L1 and
PE to connect the charging system to the mains via
one phase.
Configure the maximum charging current of 6 A to
16 A using rotary switch S3, as shown in Fig. 6 - no. 4.
0 = 6 A (default setting), 1 = 8 A, 2 = 10 A, 3 = 12 A,
4 = 14 A, 5 ... 9 = 16 A
Optional: Prepare the data cables (Digital In (EN)
/ Digital Out (SW) and LAN) and connect them as
shown in Fig. 6 - no. 2 and no. 3 . Remove the cable
bridge before connecting an external blocking device
via Digital In.
Fit the strain relief as shown in Fig. 6 - no. 5 and fix the
data cables using cable ties. Mount the lower cover of
the charging system as shown in Fig. 7.
6
7
S3
EN
max. 2.5 Nm
English
3
4
5
29