Descargar Imprimir esta página

Mettler Toledo IND310drive Manual De Instalación página 20

Ocultar thumbs Ver también para IND310drive:

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

IND310drive Installation Manual
POWERCELL Connections
POWERCELL load cells are connected to the POWERCELL board located inside the
IND310drive terminal. J1 and J2 connectors are located as shown in Figure 2-9.
The POWERCELLs should be wired to each PCB as shown in Table 2-2.
The terminal power supply will support up to ten POWERCELLs. If an external power
supply is connected to J2, a total of 24 POWERCELL load cells are supported for the
entire terminal, no matter how many POWERCELL boards are used.
Other Peripherals
Other peripheral connections include:
2-6
Figure 2-9: POWERCELL Board Connector Locations
Table 2-2: POWERCELL Connector Termination
J1 Pin #
J2 Pin #
Serial Port
Ethernet
External Keyboard
Function
1
COM A
2
COM B
3
Ground
4
Ground
5
Ground
6
+12 VDC
7
+12 VDC
8
+12 VDC
Function
1
+24 VDC
2
Ground
J2
Pin 1
J1
Pin 1

Publicidad

loading