1.4.2 "Remote "On/Off" control" option
• This option allows the "remote On/Off" function to be enabled by way of a switch installed remotely.
• To connect, couple the remote "On/Off" switch (not provided) to terminals 3 - 4 (dry contact).
• When the contact 3 - 4 is open:
- The device cannot be started in any way.
- The "OFF" message (see image
image
) if the device is on, or "---" (see image
❷ Use
2.1 I Operating principle
The heat pump uses the calories (heat) in the air to heat up your pool's water. The process to heat your pool's water to
the temperature you want may take a few days as it depends on the weather conditions, the heat pump's power and the
difference between the water temperature and the temperature you want.
The heat pump is ideal for maintaining temperature.
The hotter and more humid the air, the better your heat pump will perform.
Tip: to improve the heating and maintaining of your pool's temperature
• Anticipate the commissioning of your pool far enough in advance before you use it.
• For the temperature rise, set the water circulation to continuous (24/24) in "Boost" mode.
• To maintain the temperature throughout the season, run "automatic" circulation for the equivalent of the
water temperature divided by two (the longer this time, the more sufficient the operating range of the
heat pump to heat the pool), in "SMART" or " SILENCE" mode.
• Cover the pool with a sheet (bubble canopy, canvas, etc.) to prevent heat loss.
• Take advantage of a period with mild outdoor temperatures (on average > 10°C at night); it will be even
more effective if it runs during the warmest hours of the day.
• Keep the evaporator clean.
• Set the temperature you want and let the heat pump run.
• Connect the "Heating priority"; the filtration pump and heat pump operating time will be set according
to requirements.
: heat pump terminal board
: remote "on/off" switch (not supplied)
: separate connection cable (not supplied)
) alternates with the current display: the measured water temperature (see
) if the device is switched off.