❸ Maintenance
3.1 I Winterising
• Winterising is vital to prevent the condenser breaking due to freezing. This is not covered by
the warranty.
• To avoid damaging the appliance with condensation, do not fully cover it; a winterising cover
is provided.
• Set the regulator to "standby" mode by pressing and holding
• Open valve B,
• Close valves A and C and open valves D and E (if present),
• Make sure that there is no water circulating in the heat pump,
• Drain the water from the condenser (risk of freezing) by unscrewing the two water inlet and outlet connectors on the
back of the heat pump,
• In the case of full winterising for the pool (complete shutdown of the filtration system, bleed the filtration circuit
or even pool drainage): re-fit the two connectors by one turn to prevent any foreign bodies from getting into the
condenser,
• In the case of winterising for the heat pump only (shutdown of the heating only, the filtration keeps running): to not
tighten the connectors but add 2 caps (provided) on the condenser's water inlets and outlets.
• Put the aired winterising micro cover (provided) on the heat pump passing the hydraulics connections up through the
opening provided for that purpose on the cover. It is not necessary to disconnect hydraulic and electrical connections.
Front
3.2 I Maintenance
• Before any maintenance work on the appliance, you must cut the electricity supply as there is
a risk of electric shock which may cause material damage, serious injury or even death.
• Before any maintenance, troubleshooting or repair operation, deactivating the modem's
Wi-Fi connection is recommended to avoid any risk of the appliance being remotely controlled.
• Do not disconnect the electricity supply when the appliance is running.
• If the electric power supply is interrupted, wait a minute before restoring power to the
appliance.
• It is recommended that the appliance undergo general servicing at least on a yearly basis
to ensure proper operation, maintain performance levels and potentially prevent certain
failures. These operations are carried out at the user's expense by a technician.