Descargar Imprimir esta página

Zodiac Z350iQ Manual De Instalación Y De Uso página 8

Ocultar thumbs Ver también para Z350iQ:

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 135
1.1 I Selecting the location
1.1.1 Installation precautions
• The appliance should be installed at a distance of at least 2 metres from the edge of the pool.
• Do not lift the appliance by the body; use its base.
• Provide free space around the appliance (see § "1.1.3 Recommendentions for selecting the appliance location").
• The appliance can be installed indoor or outdoor without restrictions on operating area.
• Place the appliance on its anti-vibration studs (integrated under its base) on a stable, solid and level surface.
• This surface must be able to bear the weight of the appliance (in particular in the case of installation on a roof, a
balcony or any other support).
The appliance must not be installed:
• With the blowing towards a permanent or temporary obstacle (awning, brushwood, etc.) less than 5 metres away,
• On brackets,
• Within range of water or mud jets, sprays or run-off (take the effect of the wind into account),
• Near a heat source or flammable gas,
• Near high-frequency equipment,
• In a location where it would be subject to snow build-up,
• In a location where it might be flooded by the condensates produced by the appliance when operating.
Tip: to reduce noise produced by your heat pump
• Do not install it under or facing a window.
• Do not tilt it towards your neighbours.
• Install the appliance in an open space (sound waves are reflected on surfaces).
• Install an acoustic screen around the heat pump, respecting the distances.
• Install 50cm of flexible PVC pipe at the heat pump water inlet and outlet (to stop vibrations).
• "SILENCE" mode reduces the sound level and improves the appliance's COP. However, we recommend
using this mode simply to "maintain temperature" and increasing the filtration time by about 50%.
1.1.2 Rotating the user interface
In its factory configuration, the user interface is positioned in the corner that is diametrically opposite to the hydraulic
connections. To better match all types of installations, the top cover can be rotated to position the user interface on
the two corners adjacent to the one used in the factory configuration. Do not position the user interface directly
above the hydraulic connections.
6
❶ Installation

Publicidad

loading