Mixer Functions; Selecting The Positions That Recording Signals Are Sent From Each Channel - Tascam Model 12 Manual Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Mixer functions

Selecting the positions that recording signals are sent from each channel

The signals that are sent from each channel for recording to an SD card can be set to before or after the compressor or after the equalizer.
1.
When the recorder is stopped, select MIXER on the MENU
Screen, and open the MIXER Screen. (see "Menu operation
procedures" on page 29)
2.
Select MTR/USB SEND POINT on the MIXER Screen, and
open the MTR/USB SEND POINT Screen.
NOTE
Press the F4
button to change the settings for all
channels at the same time.
MTR/USB SEND POINT screen settings
The audio sent by computor depends on the Model 12 MODE switch settings and the MTR/USB SEND POINT screen settings.
MTR/USB SEND POINT
COMP
PRE COMP
Disabled
POST COMP
Enabled
POST EQ
Enabled
3.
Select the channel to be changed, and press the MULTI JOG
dial.
This opens the setting screen for the selected channel.
4.
Turn the MULTI JOG dial to select the send position.
Option
PRE COMP
(default)
POST COMP
POST EQ
NOTE
The audio sent to the computer depends on the MTR/USB
SEND POINT screen setting as follows.
5.
Press the MULTI JOG dial to confirm the setting.
The MTR/USB SEND POINT Screen reopens.
EQ
MODE switch
LIVE
Disabled
PC
MTR
LIVE
Disabled
PC
MTR
LIVE
Enabled
PC
MTR
9 - Other functions
Meaning
The signal of the channel is recorded to
the SD card before the compressor.
The signal of the channel is recorded to
the SD card after the compressor.
The signal of the channel is recorded to
the SD card after the equalizer.
Audio sent to computer
Sound from input jacks is sent.
Sound from input jacks is sent.
Sound from computer is sent.
Sound from the MTR is sent.
Sound from input jacks is sent.
Sound from computer is sent.
Sound from the MTR is sent.