Johnson JSMV2 Serie Manual De Instrucciones página 60

Publicidad

Idiomas disponibles

Idiomas disponibles

2. Use a knife to cut a small hole by follow-
ing the markings on the ratproof board.
3. Insert the ratproof board into the unit
and hold it in place tightly.
Markings
ratproof board
Step 6. Piping and binding
1. Lay the connecting piping flat on the
ground. Place the drainage hose,
refrigerant pipe, and all electrical
wiring (making sure that both ends are
arranged correctly) next to the piping.
2. Using the drainage hose as a guide,
measure and adjust the length of the
low voltage wiring, high voltage
wiring, any other electrical wiring,
and refrigerant pipe. Use cable ties to
initially fasten them in place.
3. Arrange the piping so that the
drainage hose is on the bottom, the
connecting piping is in the middle,
and the electrical wiring is at the top.
4. Use adhesive vinyl tape to begin
binding the piping together. Start
binding the tape at the bottom end
of the drainage hose, and make sure
that the connectors are secured
tightly.
Pipe/wire-hole position on both sides
Pipe/wire-hole position on the bottom
Then attach the
ratproof board
into the hole
First remove the metal
Refrigerant/drain
Pipe holeφ
67(2.6")
Refrigerant/drain
57.4(2.3")
Pipe hole
φ
Pipe/wire-hole position on back side
drainage
CAUTION
The electrical wiring, drainage hose,
and refrigerant pipe must exit the
binding in a suitable place. All binding
must be mutually connected, evenly
applied, and aesthetically pleasing.
NOTE
Only models with a ventilation
function contain ventilation ducting.
The amount and type of electrical
wiring used may vary according to
the specific model.
The ends of the ventilation ducting
and electrical wiring are different,
please check carefully before
starting to bind.
Step 7: Applying the sealant putty and
installing the wall hole cover
1. Tidy up the already bound piping.
2. Evenly apply the sealant putty to the
gaps between the piping and the wall,
then press on the putty firmly.
3. Pull the wall hole cover apart to open
it. After fastening tightly to the piping,
push it into the hole in the wall to
securely fasten it to the wall and
complete the installation.
V.3
Refrigerant/drain
Pipe hole
φ67(2.6")
electrical wiring
refrigerant pipe
22