OPTIONAL FUNCTION
No.
Item
Optional function
Setting temperature in 0.5
106
P1
ºC steps
107
Not used
P2
Temperature sensor
108
P3
displayed
109
Not used
P4
Display of setting
110
temperature when operation
P5
mode is Fan
111
Operation of the ECO button
P6
Prohibition of menu screen
112
P7
transition
113
Not used
P8
114
Not used
P9
115
Daylight saving time
PA
116
Not used
Pb
117
Not used
PC
118
Not used
91
119
Not used
92
120
Not used
93
121
Not used
94
122
Not used
95
123
Not used
96
124
Not used
97
125
Not used
98
126
Not used
9g
127
Not used
9A
128
Not used
9b
20
PMML0497 rev.1 - 12/2020
Individual
Settings
Setting
Enabled (0.5 °C steps)
00
(factory setting)
×
01
Disabled (1 °C steps)
00
-
-
01
00
Inlet air thermistor (Tin)
01
Outdoor air thermistor (Tout)
×
02
Remote controller thermistor (RCS)
03
Remote sensor (THM4)
00
-
-
01
00
Shown
×
01
Hidden
ECO button enabled (factory
00
setting)
×
01
ECO button disabled
Function disabled
00
(factory setting)
×
01
Function enabled
00
-
-
01
00
-
-
01
00
1 hour
×
01
2 hours
00
-
-
01
00
-
-
01
00
×
-
01
×
-
-
×
-
-
×
-
-
×
-
-
00
-
-
01
00
-
-
01
00
-
-
01
00
-
-
01
00
-
-
01
-
00/01
-
Setting conditions
This function is used to define
whether setting temperature is
adjusted in 0.5 ºC steps (when set
to "00") or in 1 ºC steps (when set
to "01").
This setting also determines
whether the resolution of
temperature differential of the
thermistor is 0.5 ºC (when set to
"00") or 1 ºC (when set to "01").
Use at 00 conditions
This function is used to select the
thermistor whose temperature is
displayed.
Use at 00 conditions
This function is used to hide the
display of setting temperature
during operation in fan mode.
The operation of ECO button is
disabled when P6 is set to 01
This function is used to prohibit the
access to the menu screens.
The text "Display disabled"
appears on screen instead.
Use at 00 conditions
Use at 00 conditions
This function is used to set the
amount of adjustment when
daylight saving time is applied.
Use at 00 conditions
Use at 00 conditions
Use at 00 conditions
Not used
Not used
Not used
Not used
Use at 00 conditions
Use at 00 conditions
Use at 00 conditions
Use at 00 conditions
Use at 00 conditions
Use as 00 conditions
Description