Descargar Imprimir esta página

Toshiba Carrier RAS-15EK Serie Manual De Instalación página 8

Publicidad

Idiomas disponibles

Idiomas disponibles

INSTALLATION DIAGRAM OF INDOOR AND OUTDOOR UNITS
INSTALLATION DIAGRAM OF INDOOR AND OUTDOOR UNITS
CLEARANCES
Air inlet grille
5
Filter
3
Batteries
2
Wireless remote control
Remark :
• Details of accessory and installation parts can
be found in the accessory section.
Field Supplied Installation Parts
Part
Parts name
code
Refrigerant piping
A
Liquid side
: Ø1/4 in. (Ø6.35 mm)
Gas side
: Ø1/2 in. (Ø12.70 mm)
Pipe insulating material
B
(polyethylene foam, 5/16 in. (8 mm) thick)
C
Putty, PVC tapes
1110651824-2 EN.indd 6
1110651824-2 EN.indd 6
Conduit
6
Filter
8
Flat head
wood screw
4
Remote control holder
Vinyl tape
Apply after carrying
out a drainage test.
24 in. (600 mm) or more
only when unobstructed to
the front and both sides.
Q'ty
One
each
1
One
each
Hook
1
Installation
plate
Insert the cushion between the indoor
unit and wall, and tilt the indoor unit for
better operation.
Front
panel
Do not allow the drain hose to get slack.
Shield pipe
Make sure to run the drain hose sloped
downward.
The auxiliary piping can be connected to
the left, rear left, rear right, right, bottom
right or bottom left.
Saddle
Insulate the refrigerant pipes separately,
not together.
Extension drain hose
(Not available,
provided by installer)
Fixing bolt arrangement of outdoor unit
• Secure the outdoor unit with fi xing bolts and nuts if the unit is likely to be
exposed to strong winds.
• Use Ø5/16 in. (Ø8 mm) or Ø3/8 in. (Ø10 mm) anchor bolts and nuts.
4-1/4 in.
(108 mm)
1-1/8 in.
(28 mm)
Air outlet
23-5/8 in.
(600 mm)
6
For rear left and left piping
Wall
Cut the piping
hole slightly
sloped downward.
Right
Rear
right
Left
Rear
Bottom
right
left
Bottom left
5/16 in. (8 mm) thick heat
resisting polyethylene foam
4-15/16 in.
(125 mm)
Air inlet
3-17/32 in.
(90 mm)
12/13/13 4:58 PM
12/13/13 4:58 PM

Publicidad