IMPORTANT:
Thermal insulation of the Pipe joints: Wrap
the pipe joints with thermal insulation
material and cover after with the vinyl tape
included with your product.
Thermal insulation on pipes
Place the drain hose under the pipe.
Insulation material:
Polyethylene foam more than 6mm wide
Connecting pipes:
a.
Use two wrenches to connect the tubes of the indoor unit. Pay special attention to the
allowed tightening torque, as indicated below, to prevent tubes, flared nuts and connectors to
be deformed and damaged.
Tighten first with your fingers and then use the wrenches.
b.
Pipe size
Liquid size Ø6.35 mm (1/4")
Liquid size Ø9.53 mm (3/8")
Liquid size Ø12.7 mm (1/2")
Liquid size Ø16 mm (5/8")
Installation of exterior unit
1. Installation of the exterior unit
Secure tight with bolts and nuts to a flat and resistant floor. If installed on the wall or ceiling, make sure to fix the support well to
prevent it from moving because of vibrations or strong wind. It is recommended to use synthetic rubber on the bases of the outdoor
unit.
2. Pipe connection of outdoor unit
Remove the covers of all the valves. Connect the tubes to the 2 and 3-way valves separately, according to the appropriate
tightening torque.
3. Outdoor unit cable connection
See the section "Wiring diagram".
NOTE:
The cooling system of the product, has an initial charge of refrigerant gas from the factory.
Refer to the product identification label located on the condensing unit for loading and for the type of refrigerant; Also, refer
to the section: "select the best location" to add extra load of refrigerant by extending the distance between the evaporator
unit and the condensing unit.
Thermal insulation
Electrical supply cable
Torque
18 N.m (14.7 lb-ft)
42 N.m (25.8 lb-ft)
55 N.m (40.5 lb-ft)
65 N.m (47.9 lb-ft)
wrapped with vinyl tape
Big pipe
Thermal insulation on
pipes
Drain hose (prepared by the user)
20
Small
pipe