CHECK ENGINE INDICATOR LIGHT
See Figure 22.
The LED indicator light in the control panel will illuminate to indi-
cate a fault in the engine's fuel injection system. Please contact
customer service or a qualified service center for assistance.
CHANGING ENGINE BATTERY CHARGE
CIRCUIT FUSE
See Figure 23.
NOTICE:
Do not use a higher rated fuse other than the specified
amperage. This could cause damage to the product.
 Open the fuse holder.
 Remove the old fuse by pulling straight out.
 Insert new 7 amp ATO blade-type fuse.
 Close cover.
USING THE BATTERY MAINTAINER
See Figure 24.
When storing the generator, the battery maintainer can be con-
nected to keep the battery fully charged and ready for use.
NOTE: The battery maintainer provided should only be used with
the 12V 15AH/ 20 HR lead acid battery model RT12150 supplied
with this generator.
 Connect the battery maintainer to the power supply. Make
sure the power supply is normal household voltage, 120 volts,
AC only, 60 Hz.
STORAGE
When preparing the generator for storage, allow the unit to cool for 30 minutes then follow the guidelines below.
STORAGE TIME
Less than 2 months
 Drain gasoline from tank and dispose of in a suitable container according to state and local ordinances.
2 months to 1 year
 Drain gasoline from tank and dispose of in a suitable container according to state and local ordinances.
1 year or more
 Remove spark plug.
 Drain gasoline from tank and dispose of in a suitable container according to state and local ordinances.
 Put a tablespoon of engine lubricant into the spark plug cylinder. Turn the engine slowly with the pull
 Reinstall spark plug.
 Change engine lubricant.
After removal from storage:
 Fill with fresh gasoline.
NOTE: If storing gasoline in suitable container for later use, make sure gasoline has been treated with fuel stabilizer
according to stabilizer manufacturer's instructions.
MAINTENANCE
rope to distribute the lubricant.
 Attach the other end of the battery maintainer to the charg-
ing cable attached to the battery. The red light on the plug
will illuminate to show the battery is charging. The battery
will become slightly warm to the touch while charging. This
is normal and does not indicate a problem. When battery is
fully charged, the red light will turn green.
NOTE: If the light does not illuminate, the fuse on the charging
cable may need to be replaced. Check the fuse and replace
if needed.
 Disconnect the battery maintainer before operating the genera-
tor. Place the cover on the charging cable when not in use.
BATTERY REMOVAL AND PREPARATION FOR
RECYCLING
Consult your local waste authority for information regarding
available recycling and/or disposal options.
WARNING:
Upon removal, cover the battery's terminals with heavy-duty
adhesive tape. Do not attempt to destroy or disassemble
battery or remove any of its components. Lead acid batteries
must be recycled or disposed of properly. Also, never touch
both terminals with metal objects and/or body parts as short
circuit may result. Keep away from children. Failure to comply
with these warnings could result in fire and/or serious injury.
PRIOR TO STORING
Page 19 — English
To preserve natural resources, please recycle or
dispose of batteries properly.
This product uses lead acid batteries. Local, state
or federal laws may prohibit disposal of batteries
in ordinary trash.

Publicidad

loading