TROUBLESHOOTING
Before calling for repair, please review the list below, since the problem may not be a unit malfunction.
SYMPTOM
The Remote Control does not
work
Odours and smoke are not
removed
The CLEAN-SIGN Light lights
green even when the air is
impure
The CLEAN-SIGN Light lights
orange or red even when the air
is clean
The Plasmacluster Indicator
Light remains green (or blue)
and does not change
A clicking or ticking sound is
heard from the unit
The discharged air has an
aroma or odour.
The unit does not operate when
cigarette smoke is in the air.
The Filter Indicator Light
remains activated even after
replacing filter.
The Plasmacluster Indicator
Light or the CLEAN-SIGN Light
will not activate.
ERROR DISPLAY
LAMP INDICATION
The "Silent" Fan Speed Indica-
tor Light blinks.
REMEDY (not a malfunction)
• Have the batteries been depleted?
• Are the batteries inserted correctly?
• Is a fluorescent lighting in the room flickering due to service
life?
• Clean or Replace the filters if they appear to be heavily soiled.
(Refer to E-12,E-13)
• The air could be impure at the time the unit was plugged in.
(Refer to E-9) Pull out the plug from the electrical outlet, and
insert the plug one minute later.
• The sensitivity of the sensors become unstable when the
opening of the odour or dust sensor is dirty or is clogged.
Clean the dust around the sensor openings using a vacuum
cleaner. (Refer to E-11)
• When in Ion Control Mode ( or Clean Mode), the Plasmacluster
Indicator Light colour will not change.
• Clicking sound or ticking sound is emitted when the unit is
generating ions.
• Check to see if the filters are heavily soiled.
Replace the filters.
• Plasmacluster Air Purifiers emit small traces of ozone which
may produce an odour. These ozone emissions are well below
safety levels .
• Is the unit installed in a location that is difficult for the sensor to
detect cigarette smoke?
• Are the odour or dust sensor openings blocked or clogged?
(In this case, clean the openings.) (Refer to E-11)
• After replacing filters, connect the power cord to an outlet and
press the Filter Reset Button on the remote control. (Refer to
E-12)
• Check to see if the Display OFF Mode on the Remote Control
is selected. If so, press the Display ON/OFF Button on the
Remote Control to activate the indicator light.
(Refer to E-10)
Fan motor disconnected or abnormal.
Operation stops.
• Pressing the ON/OFF button will reset the error display, but if
error occurs again, contact the Sharp Service Centre.
E-14
REMEDY