...die Pumpe sehr laut läuft?
Ursache
Keramikhülse nicht oder
falsch eingebaut.
Keramikachse gebrochen.
8. What to do if...
english
Danger!
When working at the filter, assure that no water gets into contact with electrical interfaces.
Disconnect the power plug! In case of problems, visit our website www.eheim.de.
...Top part of filter can't be closed
Cause
Filter inserts have been
inserted wrongly.
Filter inserts are too full.
Partition not fitted properly.
Gasket not fitted properly.
...Top of filter leaks
Cause
Closing clips not closed
properly.
Sealing areas or gasket
soiled.
Sealing ring not fitted,
inserted wrongly or
damaged.
...Primer does not work
Cause
Pre-filter flap in pre-filternot
closed.
Prefilter is filled with water.
Check valve polluted/
defective.
Behebung
Keramikhülse richtig einbauen, ggf. ersetzen.
Keramikachse erneuern.
Solution
Push filter inserts and prefilter in until they lie flush on top of each
other.
Do not overfill filter inserts. If need be, clean the touching surfaces.
Push partition into the filter container until it engages correctly.
Insert correctly into the groove provided in the upper part of the filter.
Check for damage and if necessary replace.
Solution
Close all clips properly.
Clean seal areas and spray lightly with EHEIM-silicon grease spray
Order No. 4001000.
Insert sealing ring correctly or renew.
Solution
Check the pre-filter flap for pollution and, if required, clean it. The
pre-filter flap must be unobstructed (see chapter 7.3, step 13).
Empty prefilter and repeat priming. Priming only works when the
prefilter is empty.
Clean and, if required, replace the check valve (see chapter 7.3).
39