9. The high pressure system must not be started up and run
under pressure without all team members in position and
without the Operator having already directed his/her lance
toward the work area.
3.5
Safety during system maintenance
1. High pressure system maintenance must be carried out
in the time intervals set by the manufacturer who is
responsible for the whole group according to law.
2. Maintenance should always be performed by trained and
authorised personnel.
3. Assembly and disassembly of the pump and the various
components must only be carried out by authorised
personnel, using appropriate equipment in order
to prevent damage to components, in particular to
connections.
4. Always only use original spare parts to ensure total
reliability and safety.
5
TECHNICAL CHARACTERISTICS
Model
Rpm
KF30G
1000
KF32G
1000
800
KF36G
900
1000
KF40G
900
WK12
1000
WK159
1000
WK15
1000
4
Each pump has its own Serial No. XX.XXX.XXX see pos. and
an identification label, see pos. of Fig. 1 which shows:
-
Pump model and version
-
Max revs
-
Absorbed power HP - kW
-
Flow rate l/min - Gpm
-
Pressure bar - P.S.I.
Flow rate
l/min
Gpm
106
28
120
31.7
122
32.2
137
36.2
153
40
170
44.9
120
31.7
106
28
153
40
21
PUMP IDENTIFICATION
Model, version and serial number must always be
indicated when ordering spare parts
Pressure
bar
psi
180
2610
36.5
180
2610
41.2
160
2300
140
2050
130
1900
38.2
110
1595
36.8
120
1740
27.6
150
2715
30.3
120
1740
Fig. 1
Power
kW
HP
49.6
56
37
50
37
50
52
50
37.6
41.2
35
47.6