2
Synergic curves
MIG/MAG
Filler
Gas
material
type
G3/4 Si1
CO 2
G3/4 Si1
Ar 18%CO 2
CrNi 19 9
Ar 2%CO 2
AlMg5
Ar
AlSi5
Ar
Al99,5
Ar
CuAl8
Ar
CuSi3
Ar
Basic FCW
Ar 18%CO 2
Rutil FCW
Ar 18%CO 2
Metal FCW
Ar 18%CO 2
CrNi 19 9 FCW
Ar 18%CO 2
3.8 Programs screen
1
General
Allows the storage and management of 64 welding pro-
grams which can be personalised by the operator.
1/2/3/4 Functions
5 Number of the selected program
6 Main parameters of the selected program
7 Description of the selected program
8 Heading
(consult the "Main screen" section).
2
Program storage
Enter the "program storage" menu by pressing button
for at least 1 second.
44
Ø
Prog.
Prog.
(mm)
No.
Code
0.8
2
79.S1.002
1.0
3
79.S1.003
1.2
4
79.S1.004
0.8
7
79.S1.007
1.0
8
79.S1.008
1.2
9
79.S1.009
0.8
12
79.S1.050
1.0
13
79.S1.051
1.2
14
79.S1.052
0.8
17
79.S1.106
1.0
18
79.S1.107
1.2
19
79.S1.108
0.8
22
79.S1.110
1.0
23
79.S1.111
1.2
24
79.S1.112
0.8
27
79.S1.114
1.0
28
79.S1.115
29
79.S1.116
1.2
0.8
32
79.S1.094
1.0
33
79.S1.095
1.2
34
79.S1.096
0.8
37
79.S1.098
1.0
38
79.S1.099
1.2
39
79.S1.100
1.2
42
79.S1.020
1.6
44
79.S1.022
1.2
46
79.S1.024
1.6
48
79.S1.026
1.2
50
79.S1.032
1.6
52
79.S1.034
1.2
54
79.S1.086
1.6
56
79.S1.087
ù
Select the required program (or the empty memory) (5)
by rotating the encoder.
Program stored
Memory empty
Cancel the operation by pressing button (2)
Save all the current settings on the selected program by
pressing button (3)
Introduce a description of the program (7).
- Select the required letter by rotating the encoder.
- Store the selected letter by pressing the encoder.
- Cancel the last letter by pressing button (1)
Cancel the operation by pressing button (2)
Confirm the operation by pressing button (3)
The storage of a new program on an already occupied
memory location requires cancellation of the memory
location by an obligatory procedure.
.
.
.
.
.