Descargar Imprimir esta página

Daikin LMSEY1A09AVM01 Manual De Funcionamiento página 9

Ocultar thumbs Ver también para LMSEY1A09AVM01:

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 81
3 Press a button (e.g. the continuous cycle button).
Result: The status changes (e.g. from active to not active).
4.2.7
To change the status of a direct function
INFORMATION
If no button is pressed, after 20 seconds the terminal will
automatically return to the standard display.
1 Unlock the user interface. See "4.2.1  To unlock the user
interface" [ 4  7].
2 Press the PROGRAM button to enter "dir" mode.
Result: The display shows "dir".
Changing the direct function:
3 Press the PROGRAM button in the "dir" screen.
Result: The display shows the first direct function screen (e.g.
"Fr").
4 Press the UP and DOWN buttons to navigate the menu.
5 Press the "PRG" button when arrived at the direct function
screen you want to change (e.g. "Eco").
Result: You entered the direct function.
6 Press the UP and DOWN buttons to change the setting (e.g.
change to "On").
LMSEY1A09/13 + LMSEY2A19/25
Daikin LMS
4P728169-1B – 2023.07
7 Press the PROGRAM button to confirm the new setting.
Result: The display goes back to the direct function screen
(e.g. "Eco").
8 Press the UP and DOWN buttons to navigate the menu. Scroll
to the next direct function of which you want to change the
status.
When finished changing direct functions status:
9 Scroll to the "ESC" screen.
10 Press the PROGRAM button.
Result: The display goes back to the actuator/function direct
("dir") activation screen.
Meaning of direct function screens that appear on the display
Display
Description
Alr
Display alarms
Auc
Activate auxiliary output
BtE
Enable Bluetooth
CnC
Activate continuous cycle
dfM
Start defrost
Ec1
Load embedded
configuration 1
Ec2
Load embedded
configuration 2
Eco
Activate ECO mode
Fr
Firmware version
HAC
Direct access to HACCP
menu
HL
Dim Light
HU
Set humidity level
Lht
Activate lights
nFE
Enable NFC memory
reading
OnF
Unit On/Off
Pd
Activate pull down
rH
Maximum value of control
probe
rL
Minimum value of control
probe
rtL
Reset min/max control
probe
SAh
Display alarm log
Sc
Condenser probe
Sc1
Quick Set point 1
Sc2
Quick Set point 2
Sc3
Quick Set point 3
Sd
Defrost probe
SHu
Humidity probe
Sm
Outlet probe
SPr
Product probe
SrG
Control probe
St
Set control set point
StH
Set humidity set point
4 User interface
Display alarms
DOC > 0
If featured
cc > 0
If featured
If featured
/AF > 0
F2 = 3
DOE > 0
rM = 1
rM = 1
rM = 1
/Fo > 0
/Fb > 0
/FP > 0
/Fa > 0
/FR > 0
/SP > 0
Operation manual
9

Publicidad

loading

Este manual también es adecuado para:

Lmsey1a13avm01Lmsey2a19aye01Lmsey2a25aye01