Descargar Imprimir esta página

Domo DO10140 Manual De Instrucciones página 50

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 53
Shortcut
With this button you can set and switch on a preferential setting.
If you use a certain setting more often, you can set this by pressing the SHORTCUT button for three
seconds. The apparatus then remembers the settings that are switched on at the moment of pressing.
These settings can include: the user setting (MODE), set temperature, ventilation speed (FAN) and
possibly also the SLEEP setting.
The moment you press the SHORTCUT button, the apparatus will work at the previously determined
settings.
CLEANING AND MAINTENANCE
DRAINING
Permanent drain
During the "dry" mode you can use a permanent drainage.
1.
Remove the drain plug and the rubber top.
2.
Attach the drain hose on the drain.
3.
Make sure the water is drained in a save and permanent way.
Drain code P1
When you don't use the permanent drain, the non recycled condensation water, will be stored in the
water tank.
·
When the water tank is full a few beep signals will be heard and on
the display the code P1 will appear. The "cool" or "dry" mode will end
automatically. The fan will continue to operate, this is normal.
·
Move the unit over to a place where you can easily drain the water.
·
Remove the drain plug at the bottom of your unit (A) and drain the
water.
·
After fully draining the water tank, place the drain plug back on the drain
opening.
·
Restart the unit, make sure the error code P1 is no longer displayed.
When the code doesn't disappear, try turning off and on the unit a few
times. When the error code continues, please contact the after sales
service.
·
NOTE : always make sure to install the drain plug, before turning the
unit back on.
50
DO10140
2
1
A

Publicidad

loading