19. TABLE OF MALFUNCTIONS:
Malfunction
The soda water does
not flow.
The beverage is chilled
only a little.
24
The fittings do not seal
properly.
NOTE: If the defect persists even after the above steps are taken, contact a service centre.
Cause
Pressure at the inlet has
exceeded 4.0 bar.
No water supply to the wa-
ter tap.
Inlet of pressure of CO
2
not open.
Water filter blocked.
The pump runs for more
than 240 seconds at a time
(enters fault mode).
Wrong setting of the thermo
stat.
Bad air circulation.
The machine overheats.
Poorly inserted tube.
Scratches on the hose.
Removal
Reduce the pressure on the water
valve min. to 2.5 Bar.-max 4.0 Bar.
Open the valve on the water tap.
is
Open and check the inlet pressure
CO
on the cylinder and adjust the
2
pressure of CO
2
5.5 Bar.
Check or replace the water filter.
The device must be restarted by
disconnecting from the power
socket.
Turn the thermostat knob clockwise
to No. 7.
Make sure the condenser plate are
not clogged
Place the machine to a cooler
surroundings.
Pull out the tube, check to see if the-
re are not any sharp edges, possibly
shorten with knife.
Pull out and shorten for about 2cm.
min.to 4.5 Bar - max.