23. INSPECTION BEFORE EVERY USE:
1. Visual check.
2. Lead-in cable check.
3. Condenser cleanliness check (in case of excess pollution of the condenser, clean more
frequently than 1x a month).
WARNING: Do not use the device if defects or malfunctions are found.
24. PERIODIC CHECKS:
1x day: check the water level in the tank.
1x a week: check that the lead-in cable is
undamaged and that the plug is firmly in the
socket.
1x a week: check that the device is not ex-
posed to radiant heat.
25. MAINTENANCE :
The condenser must be checked for cleanliness
every month. Any dirt found must be cleaned
26
with compressed air or wiped off. Otherwise,
there is a risk of reduced cooling output or da-
maging of the cooler.
26. ENVIRONMENTAL PROTECTION:
Waste Sorting:
This product must not be disposed of in communal waste. Electrical waste in the Czech
Republic is disposed of within the Rema System (www.remasystem.cz).
In countries other than the Czech Republic, waste sorting is subject to local regulations.
Sorting waste allows recycling and reusing used products and packaging materials. Reuse
of recycled material helps protect the environment from pollution and reduces resour-
ce consumption. Local regulations may regulate the method of disposing of household
appliances at local collection points or at the point of sale.
1x a week: check that air circulation is not
obstructed.
1x a month: check the cooling unit's con-
denser and clean it regularly.
1x a month: check water purity in the devi-
ce (chiller tank), or change it if necessary.
1x a year: have an engineering inspector
check the electrical safety of the device.
Wipe the device only with a soft and, if nee-
ded, lightly moistened cloth.