Descargar Imprimir esta página

Keysight Technologies EDU33210 Serie Guia Del Usuario página 32

Publicidad

Idiomas disponibles

Idiomas disponibles

3. Enter the desired duty cycle.
Using the numeric keypad or the knob and arrows, select a duty cycle value of 75. If you are using the numeric
keypad, press Percent to finish the entry. The instrument adjusts the duty cycle immediately and outputs a square
wave with the specified value (if the output is enabled).
Configure a Pulse Waveform
You can configure the instrument to output a pulse waveform with variable pulse width and edge time. The
following steps configure a 500 ms periodic pulse waveform with a pulse width of 10 ms and edge times of 50 ns.
1. Select the pulse function.
Press [Waveform] > Pulse to select the pulse function.
32
Keysight EDU33210 Series User's Guide

Publicidad

loading