Descargar Imprimir esta página

Fanimation The Camview FPS6225BL Instrucciones De Montaje página 15

Publicidad

Idiomas disponibles

Idiomas disponibles

1. Remove the four screws in the housing. Retain the
four screws for installation Step 7. (Figure 1)
2. Carefully pull down the housing. Remove two of the
four screws in the ceiling bracket assembly. Slightly
loosen the remaining two screws. Retain the removed
two screws for reinstallation in Step 6. (Figure 2)
3. Twist and pull down the motor assembly from the
ceiling bracket. Hook the motor assembly onto the
ceiling bracket assembly. Now you can replace the
receiver. (Figure 3)
4. Prior to installing the new receiver, check to make
sure code switch settings match those of the old
receiver. Loosen the wire connectors of the old receiver.
After the new receiver is in place, connect the receiver
wires as shown. (Figure 4)
How to Replace the Receiver
Housing
Motor
Assembly
Housing
Hook
15
Figure 1
CEILING
Figure 2
CEILING
Ceiling Bracket
Assembly
Motor
Assembly
Figure 3
Figure 4