Comfort Whirlpool Bath
Electrical Connections
Risk of electric shock. Connect only to a dedicated circuit protected by a GFCI.
When using electrical products, basic precautions should always be followed:
•
Always follow local building and electrical codes.
•
Grounding is required. The unit should be installed and grounded by a qualified electrician.
A separate, dedicated 120VAC, 15 Amp GFCI circuit is required for the pump/motor.
Risk of component overheat. Do not use electric extension cord to power this unit.
Operating the motor/pump without enough water in the bathtub can cause leaking and permanent damage.
Pump and Motor
The information provided below is applicable to all Jacuzzi
Luxury Bath units.
Electrical outlets must be mounted 4˝ (101mm) above
the floor line, or in accordance with local building and
electrical codes.
Pump/Motor
-
The pump/motor requires a dedicated 120 VAC, 15
AMP GFCI protected circuit. The electrical outlet is
not provided.
-
Bonding lugs are provided on the heater and motor to
satisfy local electrical codes.
-
At initial start-up, test GFCI units for proper operation.
Follow manufacturer's instructions on proper use.
On the following corner units (Capella 55 with integral
skirt, Capella 60 with integral skirt and Tara with
integral skirt), a junction box has been provided. To
access, remove skirt access panel. See top views in
Rough-In section for location.
A dedicated and GFCI protected circuit is required for
pump/motor and is to be installed in the junction box.
The junction box is to be hard wired. The motor is
grounded to the junction box at the factory.
If the GFCI units indicate a malfunction, per manufacturer's instructions, turn OFF power and do not use the
bathtub until the source of the problem has been identified and corrected by a licensed electrician.
Installation and Operation
All manuals and user guides at all-guides.com
www.jacuzzi.com
4˝
(101mm)
120V GFCI Protected,
Dedicated Circuit (Not Supplied)
Pump/Motor
Test
Reset
Pump/Motor (Corner Units)
Capella 55 with skirt, Capella 60 with skirt, Tara with skirt -
Junction Box
Figure 6
120VAC GFCI Protected,
Dedicated Circuit
(Not Supplied)
Bonding to
Motor/Pump
Power Cord to Motor
J-Box (supplied)
Page 11