Descargar Imprimir esta página

Hilti PM 2-PG Manual De Instrucciones Original página 24

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 49
5.6
Switching the laser beams off
▶ Set the selector switch to the OFF position.
▶ The laser beam is switched off and the pendulum is locked.
5.7
Examples of applications
5.7.1
Aligning drywall tracks
5.7.2
Aligning lights
4
5.8
Checking the plumb point
1. In a high room (for example in a stairwell with a height of 10 m), make a mark (a cross) on the floor.
2. Set the laser on a flat, horizontal surface.
3. Switch the laser on and unlock the pendulum.
4. Position the laser so that the lower plumb beam coincides with the center of the cross marked on the
floor.
5. Mark the upper plumb point on the ceiling.
6. Turn the laser through 90°.
The lower plumb beam must remain on the center of the cross.
7. Mark the upper plumb point on the ceiling.
8. Repeat the procedure after pivoting the tool through 180° and 270°.
9. Form a circle on the ceiling from the 4 marked points. Measure the diameter of the circle D in millimeters
or inches and the room height RH in meters or feet.
10. Calculate the value R.
▶ The value R should be less than 3 mm (1⁄8).
▶ If the result is out of tolerance, consult Hilti
Service.
6
Care and maintenance
Care of the product
Carefully remove stubborn dirt.
Blow dust off the laser exit window. Do not touch the laser exit window with your fingers.
Use only a slightly damp cloth to clean the housing. Do not use cleaning agents containing silicone as
these can attack the plastic parts.
Maintenance
Check all visible parts and controls for signs of damage at regular intervals and make sure that they all
function correctly.
Do not use the product if signs of damage are found or if parts malfunction. Immediately have the product
repaired by Hilti Service.
After cleaning and maintenance, install all guards and protective devices and check that they are in full
working order.
To help ensure safe and reliable operation, use only genuine Hilti spare parts and consumables. Spare
parts, consumables and accessories approved by Hilti for use with your product can be found at your
Hilti Store or online at: www.hilti.group
6.1
Hilti Measuring Systems Service
Hilti Measuring Systems Service checks the scanning tool and, if deviations from the specified accuracy are
found, recalibrates it and rechecks to ensure conformity with specifications. The service certificate provides
written confirmation of conformity with specifications at the time of the test. The following is recommended:
Choose a test/inspection interval that matches usage of the device.