7.
Troubleshooting
Fault:
Alarm indicator LED 7 lights up red.
Cause:
Polarity reversed on starter cable or terminal clip has
become disconnected from the vehicle battery during
the starting process.
Remedy:
1. Switch off the BA� 2�1 by pressing the ON/OFF but-
ton (Fig. 2, Pos. 2) briefly.
2. Check the fit of the terminal clips, clean the contact
surfaces of the battery terminals and terminal clips.
8.
List of part numbers
8.1
Special accessories
Designation
Carry frame
8.2
Service parts and parts subject to
wear
Designation
Adhesive label
Robert Bosch GmbH
9.
Designation
Starting current
Back-up current
Voltage
Plastic housing (W x H x D in mm)
Weight
Length / cross-section of starter cable
Degree of protection (DIN 40050)
Operating temperature
Integral charger
Charging characteristic
Mains connection
Protection class (DIN 40530)
The battery starter BAT 251 satisfies the requirements
of the automotive industry.
10. Environmental protection
Order number
Disposal of lead batteries
1 688 003 196
The BAT 251 contains a lead battery. Please dispose of
the battery in accordance with local regulations on the
disposal of special waste.
Order number
1 681 102 543
�roubleshooting | BA� 2�1 | 19
Technical data
�he BA� 2�1 is subject to the European
directive 2002/96/EC (WEEE).
Dispose of used electrical and electronic
devices, including cables, accessories and
batteries, separately from household waste.
Make use of the local return and collection
systems for disposal.
Proper disposal of the BAT 251 prevents
environmental pollution and possible
health hazards.
1 689 979 900
en
Value
Imax = 1400 A
Imax = 50 A
UN = 12 V
216 x 405 x 277
26,4 kg
2,0 m / 25 mm²
IP 34
–10 °C to 45 °C
IUoU
230 V, 50/60 Hz
II
|
2012-10-18