ADJUSTMENT OF THE COUPLING FORCE
During coupling the motor stops automatically on torque, as soon as the fabric is in
tension charge. The level of the coupling tension may be selected by the remote control on
three levels and may be chosen using following procedure:
a - Put the awning to its half-way point
b - Perform one of the following command sequences:
+
B
C
Tn
c - Command the descent and then check that the new
settings are acceptable.
Thanks to the possibility to set the torque of coupling
force, this system works with any type of application.
The Wave Lock RX motor is set in the factory with a
coupling force of 20% of the nominal torque (e.g., 20%
of 50 Nm = 10 Nm). Using the remote control this level
can be switched to 40% or 70% depending on the
results that you wish to achieve.
SUPER-SENSITIVITY THRESHOLD SETTING
Once the super-sensitivity function on obstacle detection downward is activated (see
page 46), the hooking strength adjusting sequences are used to set the super-sensitivity
threshold.
Ex: 20% = lowest threshold = maximum downward sensitivity
40% = medium threshold = medium downward sensitivity
70% = highest threshold = minimum downward sensitivity
To re-adjust the hooking strength, it is always mandatory to deactivate the
super-sensitivity function (see page 46).
A
-only for motors up to 25 Nm-
36
A
70 %
B
40 %
20 %
C
2 sec