COMMAND MANAGEMENT FROM WHITE WIRE
UP-STOP-DOWN-STOP / UP-DOWN / UP-DOWN "DEAD MAN"
NB: The default function provided in the motors leaving the factory is UP-STOP-DOWN-
STOP for singular UP/DOWN button switch. (Not for the switch with two independent
UP-DOWN buttons!)
PROCEDURE TO CHANGE THE CONTROL MODE:
Tn: Already programmed remote control
+
B
C
Tn
The possible settings are 3 and are available in the following order:
- UP-STOP-DOWN-STOP (factory setting)
- UP-DOWN (for 2 independent buttons)
- UP-DOWN "DEAD MAN" (for 2 independent buttons)
To switch from one setting to the following, perform the sequence as many times as
necessary to reach the desired setting.
SUPER-SENSITIVITY OBSTACLE DETECTION MANAGEMENT
DURING DOWNWARDS MOVEMENT - only for motors up to 25 Nm-
Where required, for example for vertical awnings with a tensioner weight attached, it
is possible to activate/deactivate a high level of obstacle detection sensitivity during
downwards movement.
ACTIVATING THE SUPER-SENSITIVITY FUNCTION
+
B
C
Tn
DEACTIVATING THE SUPER-SENSITIVITY FUNCTION
+
B
C
Tn
N.B.: If the super-sensitivity function on obstacle detection downward is activated, it is
possible to set a sensitivity threshold through the sequences illustrated in the section
"ADJUSTMENT OF THE COUPLING FORCE" (see page 36).
B
Tn
A
Tn
A
Tn
46
C
Tn (2 sec)
+
B
C
Tn (2 sec)
+
A
B
Tn (2 sec)