Troubleshooting; Technical Data - Aventics RTC 16 Instrucciones De Servicio

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 61
AVENTICS | RTC/CKP | R402003540–BAL–001–AG | English

10 Troubleshooting

If a repair is not done properly, there is a risk of injury
or damage!
Improper repair or modifications to the cylinder may
result in the risk of injury or damage.
O When repairing a cylinder, only use spare parts and
reconditioning kits listed in the online product catalog.
Possible
Malfunction
cause
The slide
Pressure low
does not
or absent;
reach the
cushioning set
desired
too high
position
Serious
The seal is
1)
leakage
damaged.
Leakage due to
solid matter in
the
compressed
air
Cap strong
Cushioning
impacts on
incorrectly set
the cylinder
Varying
pressure
Poor run-
Oil in the
ning charac-
cylinder
teristics
Lack of lubri-
cation, e.g. due
to extreme
load
Lever too long
1)
Slight leakage is normal for this type of cylinder.
WARNING
Remedy
Check the connected
supply pressure.
Loosen the cushioning
screws.
Otherwise, check the
seal.
Check the seal and
sealing strip.
Replace if necessary.
Available as a
reconditioning kit (see
the online product
catalog).
Adjust the cushioning
as described in section
"Setting the speed and
cushioning".
Check the applied
pressure and ensure
that the conditions are
constant.
Clean and lubricate the
cylinder. Check the oil
content of the
compressed air.
Replace the piston
seals and lubricate the
cylinder.
Ensure that the
maximum permitted
lever length has not
been exceeded.

11 Technical data

Technical data
Dimensions
Weight
Operating
temperature range
Storage temperature
range
Protection class
according to
EN 60529/IEC 529
(applies to sensors)
Mounting orientation
Operating pressure
Compressed air
quality
12 Accessories
See the AVENTICS online product catalog for accessories.
Depends on the configuration
(see online product catalog)
Depends on the configuration
(see online product catalog)
-10 °C...+60 °C
-25 °C...+75 °C
IP65
IP67 if sensors with a threaded
connection are used
Any. If there is a risk of standing
water, the cylinder must be
installed with the slide
downwards.
2...8 bar
According to DIN ISO 8573-1,
class 6, 4, 3 or lower
Solid pollutants:≤5 μm
Dew point: ≤3 °C
Oil content: ≤1 mg/m
3
29

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Rtc 25Rtc 32Rtc 40Ckp 16Ckp 25Ckp 32 ... Mostrar todo

Tabla de contenido