AVENTICS | AS1 / AS2 / AS3 / AS5 | R412013438–BAL–001–AD | English
9
Conversion and Extension
Danger of injury in case of disassembly
or replacement under pressure or voltage
Disassembling or replacement when under pressure
or electrical voltage may lead to injuries and damage
to the product or system components.
O Make sure that the relevant system part is not
under voltage or pressure before you disassemble
the product or replace parts.
O Protect the system against being switched on.
Changing flow direction
5
On delivery the flow direction is from left (1, IN) to right
(2, OUT). The following conversion on the product is
necessary if the flow direction is to be changed:
Distributor conversion
On all components, the flow direction change is performed
by rotating mounting by 180° around the vertical axis.
The housing covers need to be changed for the purpose.
1. Release the housing cover at the front and back.
2. Re-attach the covers at the opposite sides with the
cover bearing the AVENTICS logo facing to the front.
Component conversion on the DIC
Components with a flow direction from left to right
need to be converted to change the flow direction
on the DIC distributor with center infeed.
10 Troubleshooting
Possible
Malfunction
cause
Pressure/flow
Operating
level is not
pressure
reached or
too low
drops off slowly.
Leak on
tubing
CAUTION
Remedy
W
Set higher operating
pressure
W
Check tubing
diameter
Check tubing and
tubing connections
11 Technical Data
Maximum permissible pressure, temperature range,
and thread connection are indicated on the products.
General data
Mounting orientation
Medium/ambient
temperature min./max.
Further technical data can be found
in our online catalog at
www.aventics.com/pneumatics-catalog.
Any
-10 °C /+50 °C
9