Noise Information
Noise emission values determined according to
EN IEC 62841-3-9.
Typically, the A-weighted noise level of the power tool is:
Sound pressure level 97 dB(A); sound power level
106 dB(A). Uncertainty K = 3 dB.
Wear hearing protection!
The noise emission value given in these instructions has
been measured in accordance with a standardised measur-
ing procedure and may be used to compare power tools. It
may also be used for a preliminary estimation of noise emis-
sions.
The noise emission value given represents the main applica-
tions of the power tool. However, if the power tool is used
for other applications, with different application tools or is
poorly maintained, the noise emission value may differ. This
may significantly increase noise emissions over the total
working period.
To estimate noise emissions accurately, the times when the
tool is switched off, or when it is running but not actually be-
ing used, should also be taken into account. This may signi-
ficantly reduce noise emissions over the total working
period.
Rechargeable battery
Bosch sells some cordless power tools without a re-
chargeable battery. You can tell whether a rechargeable bat-
tery is included with the power tool by looking at the pack-
aging.
Charging the battery
Use only the chargers listed in the technical data. Only
u
these chargers are matched to the lithium-ion battery of
your power tool.
Note: Lithium-ion rechargeable batteries are supplied par-
tially charged according to international transport regula-
tions. To ensure full rechargeable battery capacity, fully
charge the rechargeable battery before using your tool for
the first time.
Inserting the Battery
Push the charged battery into the battery holder until it
clicks into place.
Removing the Battery
To remove the rechargeable battery, press the battery re-
lease button and pull the battery out. Do not use force to do
this.
The rechargeable battery has two locking levels to prevent
the battery from falling out if the battery release button is
pressed unintentionally. The rechargeable battery is held in
place by a spring when fitted in the power tool.
Bosch Power Tools
Battery charge indicator
The green LEDs on the battery charge indicator indicate the
state of charge of the battery. For safety reasons, it is only
possible to check the state of charge when the power tool is
not in operation.
Press the button for the battery charge indicator or
show the state of charge. This is also possible when the bat-
tery is removed.
If no LED lights up after pressing the button for the battery
charge indicator, then the battery is defective and must be
replaced.
Battery model GBA 18V...
LED
3× continuous green light
2× continuous green light
1× continuous green light
1× flashing green light
Battery model ProCORE18V...
LED
5 × continuous green light
4 × continuous green light
3 × continuous green light
2 × continuous green light
1 × continuous green light
1 × flashing green light
Recommendations for Optimal Handling of the
Battery
Protect the battery against moisture and water.
Only store the battery within a temperature range of −20 to
50 °C. Do not leave the battery in your car in the summer, for
example.
Occasionally clean the ventilation slots on the battery using a
soft brush that is clean and dry.
A significantly reduced operating time after charging indic-
ates that the battery has deteriorated and must be replaced.
Follow the instructions on correct disposal.
Assembly
Remove the battery from the power tool before carry-
u
ing out work on the power tool (e.g. maintenance,
changing tool, etc.). The battery should also be re-
moved for transport and storage. There is risk of injury
from unintentionally pressing the on/off switch.
English | 19
to
Capacity
60–100 %
30–60 %
5–30 %
0–5 %
Capacity
80–100 %
60–80 %
40–60 %
20–40 %
5–20 %
0–5 %