Descargar Imprimir esta página

Hatco HSBF Serie Instrucciones Originales página 17

Estantes térmicos empotrados

Publicidad

Idiomas disponibles

Idiomas disponibles

Flush Remote Mounted Control Enclosures
Two flush-style remote mounted control enclosures are
available — the Mechanical Temperature Control enclosure and
the Digital Temperature Controller enclosure. Both enclosures
are installed using the following procedure.
WARNING
ELECTRIC SHOCK HAZARD: Remote mounted control
enclosure must be mounted on a vertical wall and
installed in vertical position. Mounting control enclosure
in horizontal position may result in collection of liquids
and lead to an electric shock.
NOTICE
Install remote mounted control enclosure outside of heat
zone. Locating control enclosure inside heat zone will
cause control(s) to overheat, malfunction, and fail.
Do not modify wiring or cut thermostat capillary on
control box to increase remote mounting distance. Cutting
thermostat capillary will cause unit to overheat and may
damage unit as well as surrounding countertop.
NOTE: A qualified electrician is recommended for connecting
the units to a power source.
1. Prepare cutout and pre-drill screw holes.
a. Refer to the "Flush Remote Mounted Control Enclosure
Installation Dimensions" illustration for cutout and screw
hole dimensions.
b. Perform the cutout and pre-drill the screw holes.
2. Remove trim cover from control enclosure assembly.
3. Position control enclosure into opening through the
backside.
4. Secure control enclosure to mounting surface using screws
(not supplied).
5. Connect proper power source to the mounted remote
control enclosure.
6. Reinstall trim cover.
Flush Remote Mounted Control Enclosure Installation Dimensions
149 mm
(5-7/8")
173 mm
(6-7/8")
98 mm
(3-7/8")
Front View of Cutout
HSBFCEM1-0523
IMPORTANT NOTE:
Make sure the installation
location provides enough
room
for
connections to the control
enclosure.
162 mm
(6-3/8")
17
OPTIONS AND ACCESSORIES
NOTE: Units are equipped with a 914 mm (3') flexible conduit
connecting the control enclosure to the unit. The digital
temperature controller also offers 1829 mm (6') and
3048 mm (10') conduit lengths.
Power I/O (on/off) Switch
Both flush-style remote mounted control enclosures are
equipped with a Power I/O switch. Move the Power I/O switch
to the I (on) position to turn on the unit. The indicator light in the
switch glows when the unit is on.
Changing the Setpoint Temperature — Mechanical
Temperature Control
Turn the temperature control clockwise to increase the setpoint
temperature. Turn the temperature control counterclockwise to
decrease the setpoint temperature.
Temperature Control
Power I/O (on/off) Switch
Mechanical Temperature Control
Mechanical Control
electrical
Trim Cover
Side View of Installed Enclosure
Digital Controller
121 mm (4-3/4")
102 mm (4")
Control Enclosure
Mounting Surface

Publicidad

loading