Problem/Symptom
Red light flashes.
Note: If tool has jammed and the mechanism initiates an automatic recovery, the tool may make a series of clicks as it repositions the driver.
This is normal.
Tool will not start or runs slowly.
Tool does not drive fastener to desired depth.
Tool runs but will not drive fastener.
Poor feed/ tool jamming.
Broken or worn driver.
Tool does not fully return.
TROUBLESHOOTING
Probable Cause
Fastener jam.
Tool does not function.
Battery is discharged or has dead cell.
Workpiece contact element is jammed.
Drive piston has failed.
Workpiece contact element or trigger
switches are damaged.
Improper depth-of drive setting.
Tool not pressed firmly against the workpiece.
Drive application is too rigorous.
Pressure loss.
Battery is discharged or has a dead cell.
Nail jam in guidebody.
Mechanism requires repair.
Tool is overheated.
Driver tip not located above fastener.
Debris build-up in mechanism.
Driver tip not located above fastener.
Weak battery.
19
Corrective Action
Remove battery and re-start.
Tool will attempt to recover.
Remove battery again.
Check if nail is blocking next fastener.
Inspect magazine for bent nail.
Remove magazine and inspect guide body.
Return to service center for repair.
Replace or recharge battery.
Remove battery, then inspect tool to assure
free movement of workpiece contact element.
Return tool to authorized SENCO service
representative.
Return tool to authorized SENCO service
representative.
Refer to operators manual for proper
adjustment.
Hold tool firmly in place when driving fastener.
Refer to operators manual for appropriate
applications.
Return tool to authorized SENCO service
representative.
Recharge or replace with fresh battery.
Refer to operators manual for jam-clearing
instructions.
Return tool to authorized SENCO service
representative.
Allow tool to cool and insert fresh battery.
Recharge battery and allow tool to automati-
cally retract driver.
Clean tool, clean magazine or inspect feeder
spring.
Return tool to authorized SENCO service
representative.
Recharge battery and allow tool to automati-
cally retract driver.
EN