START-UP

The Pressure Switch is Pre-set at the required pressure. The range and
differential settings ARE NOT adjustable. The Pressure Switch should not be
tampered with in any way and no attempt should be made to adjust the
pressure settings as this could damage the Switch to the point of failure
and/or void any warranty for the Pressure Switch.
1.
Close the service valve.
2.
Release any remaining tank pressure by slowly opening the
manual drain valve.
.
Close the manual drain valve and apply power to the compressor.
If the pressure switch is equipped with an "ON/ AUTO-OFF" lever,
flip the switch to the "ON/AUTO" position. If the unit is equipped
with a control panel "ON/OFF" switch, move the switch to the
"ON" position

TYPICAL PRESSURE SWITCH LEVER (IF EQUIPPED)

TYPICAL CONTROL PANEL SWITCH (IF EQUIPPED)

4. Slowly open the service valve.

TYPICAL SERVICE VALVE (A = OPEN, B = CLOSED)

CAUTION
Unusual noise or vibration indicates a problem�� Do not continue
to operate until you identify and correct the source of the
problem��
NOTICE
Ensure the direction of rotation is correct per the arrow on
the motor�� If the rotation is incorrect on three-phase units,
interchange any two of the three leads��
EN-8
RELEASED 14/Mar/2018 13:53:20 GMT

OPERATION

OIL CONSUMPTION CHECK

A rule of thumb in determining a "passing grade" for oil consumption is to
consider consumption at or above 50 horsepower-hours per ounce to be
acceptable. The formula is as follows:
Horsepower X Hours of Operation = Horsepower Hours
Ounces of Oil Used
To apply this formula, consider the size of the machine. In the following
example, a 5 horsepower compressor uses 2 ounces of oil every 20 hours
of operation.
5 Horsepower X 20 Hours of Operation
The compressor in the example passes the oil consumption test.
New or rebuilt compressor pumps will discharge higher
than normal amounts of oil until the piston rings are seated
(approximately 100 operating hours)��
per Ounce
= 50 Horsepower
2 Ounces of Oil Used
NOTICE
Hours per Ounce
22207666 Rev. C