Respect the following recommendations dur-
ing installation:
- It is necessary to foresee making adjust-
ments or access to the side of the hood in
which the duct will be connected before clos-
ing the false ceiling.
- The ceiling in which the hood is located must
be completely smooth and must not have any
differences in height or inclines of any type.
- For good functioning of these models, locate
the aeration grills in the lower part of some
walls of the room so as to have an adequate
continuous air flow at the selected power.
- The maximum distance between the FLOOR
and the FALSE CEILING must not exceed 2.5
metres.
- For models and versions supplied with ex-
ternal, ceiling or wall motors, positioning the
motor must be considered, because it must
be easily accessible, safe and with enough
work space adequate for the dimensions of
the motor so that any repair or maintenance
interventions can be carried out efficiently by
technical assistance.
- Once the correct motor has been chosen,
consider the maximum distance between the
hood and the motor. Refer to the table of mo-
tor technical specifications.
- In the more powerful V2300 and V2500 mo-
torisations, the minimum distance between
the hood and the motor is 4 metres. The rec-
ommended distance is 4 to 6 metres. If it is
positioned closer, problems could occur con-
nected to high noise level. Furthermore, it is
advisable to install these types of motor with
a SEC sound-proofed duct (not included as
standard, but can be supplied as an optional;
contact the distributor).
- In any case, the cooking hob must be cen-
tred and always be of lesser dimensions in re-
spect of the hood; it must extend beyond the
edge of the cooking hob at least 10 cms. in all
directions.
- Refer to the specific manual contained in the
packaging for versions with an external motor
and their relative installations.
INSTALLATION
E200/150 – E200/110 – E205/110 V1100 -
E280/90.
Fit a false ceiling with an opening of the fol-
lowing sizes:
E200/150: 1465x965 mm with a minimum
distance of 270 mm between the ceiling and
the false ceiling;
E200/110: 1065x665 mm with a minimum
distance of 270 mm between the ceiling and
the false ceiling.
E205/110 V1100: 1065x665 mm with a min-
imum distance of 270 mm between the ceil-
ing and the false ceiling.
E280/90: 865x405 mm with a minimum dis-
tance of 270 mm between the ceiling and the
false ceiling.
It is possible to select the side of the hood
where the air suctioned can be discharged.
After having chosen the most suitable posi-
tion, prepare the ducting: an air outlet con-
nection piece, with a diameter of 150 mm to
be installed in the side selected, is provided
with the appliance.
Special accessories of the same diameter are
supplied for Ø200mm motors.
Leave any unused exhaust outlets closed.
Draw the outline of the hole to house the ceil-
ing-mounted hood on the solid ceiling (Fig.
1), according to the model chosen; make 4
holes in the ceiling according to the dimen-
sions shown in (Fig. 2); place the metric plugs
provided in the holes.
Open the stainless steel panels, following
the instructions mentioned in the USES sec-
tion, and remove the grease filters in order
to avoid damaging them in any way and too
allow installation (Fig. 3); screw the thread-
ed bars provided into the plugs (Fig.4); the
threaded bars are 250 mm long and serve
to install the ceiling-mounted hood at a dis-
tance from the solid ceiling of between 270
mm and 370 mm (Fig. 5); in case of a larger
gap between the hood and the ceiling, you
need to use longer threaded bars.
19